• Green Guide 2008 ratings

    Green Guide 2008 ratings

    Building type >
    Category >
    Element type >
    Flat Roof: Warm Deck

      Element number Summary
    rating
    Beam and dense block deck, vapour control layer, insulation, Polyester cold applied liquid waterproofing membrane system. 1212540079 C
    Beam and dense block deck, vapour control layer, insulation, Polymethylmethacrylate cold applied liquid waterproofing membrane system. 1212540062 B
    Beam and dense block deck, vapour control layer, insulation, Polyurethane cold applied liquid waterproofing membrane system. 1212540070 C
    In situ reinforced concrete slab with 50% GGBS and 20% recycled coarse aggregate, vapour control layer, insulation, EPDM single ply roofing membrane 1212540045 C
    In situ reinforced concrete slab with 50% GGBS and 20% recycled coarse aggregate, vapour control layer, insulation, felt isolating layer, mastic asphalt roofing 1212540046 D
    In situ reinforced concrete slab with 50% GGBS and 20% recycled coarse aggregate, vapour control layer, insulation, oxidised polyester reinforced bitumen roofing membranes with mineral finish 1212540047 C
    In situ reinforced concrete slab with 50% GGBS and 20% recycled coarse aggregate, vapour control layer, insulation, Polyester cold applied liquid waterproofing membrane system. 1212540080 C
    In situ reinforced concrete slab with 50% GGBS and 20% recycled coarse aggregate, vapour control layer, insulation, polymer modified polyester reinforced bitumen roofing membranes with mineral finish 1212540048 C
    In situ reinforced concrete slab with 50% GGBS and 20% recycled coarse aggregate, vapour control layer, insulation, Polymethylmethacrylate cold applied liquid waterproofing membrane system. 1212540063 C
    In situ reinforced concrete slab with 50% GGBS and 20% recycled coarse aggregate, vapour control layer, insulation, Polyurethane cold applied liquid waterproofing membrane system. 1212540071 C
    In situ reinforced concrete slab with 50% GGBS and 20% recycled coarse aggregate, vapour control layer, insulation, PVC single ply roofing membrane 1212540049 C
    In situ reinforced concrete slab with 50% GGBS and 20% recycled coarse aggregate, vapour control layer, insulation, TPO single ply roofing membrane 1212540050 C
    In situ reinforced concrete slab, vapour control layer, insulation, EPDM single ply roofing membrane 1212540016 C
    In situ reinforced concrete slab, vapour control layer, insulation, felt isolating layer, mastic asphalt roofing 1212540012 D
    In situ reinforced concrete slab, vapour control layer, insulation, oxidised polyester reinforced bitumen roofing membranes with mineral finish 1212540013 D
    In situ reinforced concrete slab, vapour control layer, insulation, Polyester cold applied liquid waterproofing membrane system. 1212540075 D
    In situ reinforced concrete slab, vapour control layer, insulation, polymer modified polyester reinforced bitumen roofing membranes with mineral finish 1212540014 C
    In situ reinforced concrete slab, vapour control layer, insulation, Polyurethane cold applied liquid waterproofing membrane system. 1212540067 D
    In situ reinforced concrete slab, vapour control layer, insulation, PVC single ply roofing membrane 1212540017 C
    In situ reinforced concrete slab, vapour control layer, insulation, TPO single ply roofing membrane 1212540018 C
    Precast concrete formwork with lattice reinforcement and in situ concrete, vapour control layer, insulation, EPDM single ply waterproofing membrane 1212540015 C
    Precast concrete formwork with lattice reinforcement and in situ concrete, vapour control layer, insulation, mastic asphalt roofing 1212540007 D
    Precast concrete formwork with lattice reinforcement and in situ concrete, vapour control layer, insulation, oxidised polyester reinforced bitumen roofing membranes with mineral finish 1212540010 C
    Precast concrete formwork with lattice reinforcement and in situ concrete, vapour control layer, insulation, Polyester cold applied liquid waterproofing membrane system. 1212540074 C
    Precast concrete formwork with lattice reinforcement and in situ concrete, vapour control layer, insulation, polymer modified polyester reinforced bitumen roofing membranes with mineral finish 1212540011 C
    Precast concrete formwork with lattice reinforcement and in situ concrete, vapour control layer, insulation, PVC single ply waterproofing membrane 1212540008 C
    Precast concrete formwork with lattice reinforcement and in situ concrete, vapour control layer, insulation, TPO single ply waterproofing membrane 1212540009 C
    Precast prestressed concrete hollow slab, with screed, vapour control layer, insulation, EPDM single ply waterproofing membrane 1212540022 B
    Precast prestressed concrete hollow slab, with screed, vapour control layer, insulation, felt isolating layer, mastic asphalt roofing 1212540019 C
    Precast prestressed concrete hollow slab, with screed, vapour control layer, insulation, oxidised polyester reinforced bitumen roofing membranes with mineral finish 1212540020 C
    Precast prestressed concrete hollow slab, with screed, vapour control layer, insulation, Polyester cold applied liquid waterproofing membrane system. 1212540076 C
    Precast prestressed concrete hollow slab, with screed, vapour control layer, insulation, polymer modified polyester reinforced bitumen roofing membranes with mineral finish 1212540021 B
    Precast prestressed concrete hollow slab, with screed, vapour control layer, insulation, Polyurethane cold applied liquid waterproofing membrane system. 1212540068 C
    Precast prestressed concrete hollow slab, with screed, vapour control layer, insulation, PVC single ply waterproofing membrane 1212540023 B
    Precast prestressed concrete hollow slab, with screed, vapour control layer, insulation, TPO single ply waterproofing membrane 1212540024 B
    Precast prestressed concrete hollow slab, with screen, vapour control layer, insulation, Polymethylmethacrylate cold applied liquid waterproofing membrane system. 1212540061 C
    Profiled metal "deep" decking with in situ concrete, vapour control layer, insulation, EPDM single ply roofing membrane 1212540051 B
    Profiled metal "deep" decking with in situ concrete, vapour control layer, insulation, felt isolating layer, mastic asphalt roofing 1212540025 C
    Profiled metal "deep" decking with in situ concrete, vapour control layer, insulation, oxidised polyester reinforced bitumen roofing membranes with mineral finish 1212540052 C
    Profiled metal "deep" decking with in situ concrete, vapour control layer, insulation, Polyester cold applied liquid waterproofing membrane system. 1212540081 C
    Profiled metal "deep" decking with in situ concrete, vapour control layer, insulation, polymer modified polyester reinforced bitumen roofing membranes with mineral finish 1212540026 B
    Profiled metal "deep" decking with in situ concrete, vapour control layer, insulation, Polymethylmethacrylate cold applied liquid waterproofing membrane system. 1212540064 C
    Profiled metal "deep" decking with in situ concrete, vapour control layer, insulation, Polyurethane cold applied liquid waterproofing membrane system. 1212540072 C
    Profiled metal "deep" decking with in situ concrete, vapour control layer, insulation, PVC single ply roofing membrane 1212540053 B
    Profiled metal "deep" decking with in situ concrete, vapour control layer, insulation, TPO single ply roofing membrane 1212540054 B
    Structural steel trusses, galvanised steel purlins and deck, vapour control layer, insulation, EPDM single ply roofing membrane 1212540001 A+
    Structural steel trusses, galvanised steel purlins and deck, vapour control layer, insulation, felt isolating layer, mastic asphalt roofing 1212540002 A
    Structural steel trusses, galvanised steel purlins and deck, vapour control layer, insulation, oxidised polyester reinforced bitumen roofing membranes with mineral finish 1212540005 A+
    Structural steel trusses, galvanised steel purlins and deck, vapour control layer, insulation, Polyester cold applied liquid waterproofing membrane system. 1212540073 A
    Structural steel trusses, galvanised steel purlins and deck, vapour control layer, insulation, polymer modified polyester reinforced bitumen roofing membranes with mineral finish 1212540006 A+
    Structural steel trusses, galvanised steel purlins and deck, vapour control layer, insulation, Polymethylmethacrylate cold applied liquid roofing membrane system. 1212540060 A+
    Structural steel trusses, galvanised steel purlins and deck, vapour control layer, insulation, Polyurethane cold applied liquid waterproofing membrane system. 1212540066 A
    Structural steel trusses, galvanised steel purlins and deck, vapour control layer, insulation, PVC single ply waterproofing membrane 1212540003 A+
    Structural steel trusses, galvanised steel purlins and deck, vapour control layer, insulation, TPO single ply waterproofing membrane 1212540004 A+
    Timber joists, OSB/3 decking, vapour control layer, insulation, Polyester cold applied liquid waterproofing membrane system. 1212540078 A+
    Timber joists, plywood (temperate EN 636-2) decking, vapour control layer, insulation, OSB (18mm), GRP roofing laminate with GRP edge trim 1212540055 A+
    Timber joists, plywood (temperate EN 636-2) decking, vapour control layer, insulation, Polyester cold applied liquid waterproofing membrane system. 1212540077 A
    Timber joists, plywood (temperate EN 636-2) decking, vapour control layer, insulation, Polyurethane cold applied liquid waterproofing membrane system. 1212540069 A

     

    For more information

    Call us on 0333 321 88 11 if you would like to know more, or email enquiries@bregroup.com.